6 Wire Gfci Wiring Diagram
In case of three phase spa wiring use 12 or 10 gauge wire size for each line.
6 wire gfci wiring diagram. Please make sure to turn off power when putting your new gfci in. The above diagram shows the gfci wiring to multiple outlet as in white while the pictures are same. Here the gfci outlet the switch and disposal are all protected from ground faults. The yellow piece of equipment is called a three prong tester.
If a load plugged into the outlet or the disposal causes a short the whole device will trip and neither will work until the danger is removed. Gfci combo switch and outlet wiring circuit diagrams and installation. If you are replacing an existing gfci outlet with a new one we suggest that you read our page about replacing a gfci outlet. As discussed before gfci also known as ground fault circuit interrupter is a protection device against electric shock which detects the ground faults and leakage currents especially in outdoor and watery areas such as bathroom kitchen laundry etc.
7 all supply wires must be copper and rated at a minimum 194 f 90 c. One side of the gfci connected to the ground neutral wire as shown white in the diagram and another side to the high potential hot wire shown as black in the diagram shows as in black color. How to wire gfci combo switch and outlet gfci switch outlet wiring diagrams. This requirement may be filled with the gfci circuit breaker and sub panel.
How to wire gfci outlets. This way the switch and light bulb is gfci protected. Fully explained wiring instructions complete with a picture series of an installation and wiring diagrams can be found here in the gfi and light switch area here in this website. Also make sure that the amp hz hertz and voltage of the gfi.
Just click the wiring diagrams wiring a gfci outlet with a switch how to wire a gfci outlet with a switch there are a few different methods that are used to. Wiring a gfci outlet and a light switch. Wiring a gfci outlet with a light switch. Use 8 or 6 0mm 2 wire for the same 12kw spa three phase 208v where the max current is 33 3 amp.
Wiring for a switch and gfci receptacle in the same box is also shown. For example use 12 or 4 0mm 2 wire for up to 12kw three phase 415v 480v where the max current is 18 2a. 6 the electrical circuit to the spa must include a class a type ground fault circuit interrupter gfci as required by the nec for the electrical wiring. This diagram illustrates wiring a gfci receptacle and light switch in the same outlet box a common arrangement in a bathroom with limited space.
This diagram illustrates the wiring for a cooper gfci combo switch device to control a garbage disposal. You can also learn about wiring gfci outlets in the following 7 steps. In case of higher wattage use the proper wire size according to the table and use manual.