Bathroom Gfci Outlet Wiring Diagram
The hot source is spliced to the line terminal on the receptacle and to one terminal on the light switch.
Bathroom gfci outlet wiring diagram. Hydro massage bathtubs and their associated electrical components must have gfci ground. All bathroom exhaust fans shall provide a minimum of 5 air changes per hour. Wiring a gfci receptacle is a little more complicated than hooking up a regular outlet but easily learned once explained. A 20 amp receptacle circuit for plug in appliances.
Gfci combo switch and outlet wiring circuit diagrams and installation. A 15 amp circuit is minimum but this is often a 20 amp circuit especially if there is a heat lamp integrated into this circuit. Bathroom outlets must be protected by a gfci device. All receptacles must be afci and gfci protected either by circuit breakers or individual receptacles that offer afci and gfci protection.
Home electrical wiring includes 110 volt outlets and 220 volt outlets and receptacles which are common place in every home. This circuit shall have no other outlets except bathroom receptacles. Gfci outlet wiring wiring diagrams for gfi outlets. Wiring electrical outlet for the home.
Fully explained wiring instructions complete with a picture series of an installation and wiring diagrams can be found here in the gfi and light switch area here in this website. Wiring more than one gfi bathroom outlet. See how wiring electrical outlets for the home is installed. More about gfci devices.
Wiring a gfci outlet with a light switch. Just click the wiring diagrams wiring a gfci outlet with a switch how to wire a gfci outlet with a switch there are a few different methods that are used to. This diagram illustrates wiring a gfci receptacle and light switch in the same outlet box a common arrangement in a bathroom with limited space. Light fixtures and wall switches must be on a separate circuit.
In the first diagram the single way switch and light bulb is connected to the load terminal of gfci. More about bath exhaust fans. How to wire a bathroom gfci outlet circuit james the gfci code requires that a bathroom outlets are required to be on a dedicated 120 volt 20 amp circuit. How to wire gfci combo switch and outlet gfci switch outlet wiring diagrams.
This way the switch and light bulb is gfci protected. As discussed before gfci also known as ground fault circuit interrupter is a protection device against electric shock which detects the ground faults and leakage currents especially in outdoor and watery areas such as bathroom kitchen laundry etc. Installing additional gfci outlet wiring should be done according to local and national electrical gfci codes with a permit and be inspected. More about wiring electrical outlets.
If you are replacing an existing gfci outlet with a new one we suggest that you read our page about replacing a gfci outlet.