Bodine Emergency Led Driver Wiring Diagram
The following wiring diagrams are only applicable to everline led drivers that incorporate switch dimming control capabilities when connected with the bodine bsl17c c2 and bsl310 emergency led drivers.
Bodine emergency led driver wiring diagram. Wiring diagrams for 1 lamp emergency operation fig 119 one 1 lamp instant start ballast fig 099 one 1 lamp rapid start. This emergency driver shall consist of a high temperature maintenance free nickel cadmium battery charger and electronic circuitry contained in one case. Operates an led load of up to 10w at nominal battery voltage for a minimum of 90 minutes. Ul recognized factory installation indoor and damp output class 2 compliant bsl310 is field installable when used with the philips evokit led retrofit luminaire and installed by licensed.
An illuminated test switch its to monitor. Bodine emergency led drivers allow led fixtures to serve as emergency lighting sources. Using bodine bsl310 bsl310lp bsl36lp emergency driver selection considerations. Emergency lighting shall be provided by using an led fixture equipped with a philips bodine bsl310m universal input 120 277 v emergency driver.
Step 3 wiring the emergency driver select the appropriate wiring diagram to connect the emergency driver to the ac driver and led load. Please refer to the selection features listed below when selecting the philips bodine emergency led driver to be used in. Gtd wiring diagram faint repeat9 klictravel nl. Consult the factory for other wiring diagrams.
Wiring diagram for emergency only fixtures emergency ballast and ac ballast must be fed from the same branch circuit typical schematics only. Bodine bsl310 emergency led driver 120 277v up to 10 watt led emergency driver input voltage. To verify that this is the correct wiring diagram for your bodine product please check for the connection diagram reference number in the specifications table on the applicable item model page. The iota ilb cp10 is a ul listed and classified led emergency driver that allows the same led fixture to be used for both normal and emergency operation.
Indoor outdoor egress damp cold temperatures steplights downlights class 2 installations and more. Figure 1 wiring diagram for the distributed emergency solution for xitanium sr led driver. When either one of the switches is closed the driver provides a percentage of the full. Connection diagram for 230 460vac 9 wire reversible 3 phase gearmotors and motors 07410012.
In the event of a power failure the ilb cp10 switches to the emergency mode and operates the existing fixture for 90 minutes the unit contains a battery charger and converter circuit in a single can and is available in different mounting. May be used with other ballasts. Make sure all connections are in accordance with the national electrical code and any local regulations. After installation is complete supply ac power to the emergency driver and join the converter.
Bi level switch dimming drivers have two hot leads and a single neutral lead for input power connections.